Ozone Generator Output Calculators
Calculates the ozone output (g/hr) based on the flow rate (LPM) and ozone concentration (% by weight); the computation varies depending on the type of feed gas used. An option for direct calculation is also available which uses g/m3 as the unit of measure for ozone concentration which therefore works regardless of feed gas type.
Direct Calculation
g/hr = ((LPM x 60) x 0.001) x g/m3
Oxygen Feed Gas
g/hr = ((LPM x 0.001) x 60) x (14.3 x % by weight)
Air Feed Gas
g/hr = ((LPM x 0.001) x 60) x (12.8 x % by weight)
LPM
% wt
g/hr
Formula: ((LPM Ă— 60) Ă— 0.001) Ă— g/m3 = g/hr